View previous topic :: View next topic |
Author |
Message |
hmo
Joined: 14 Feb 2003 Posts: 81 Location: Denmark
|
Posted: Tue Jul 22, 2003 8:37 am Post subject: |
|
|
Hi Alex.
When checking processes by RMA (remote server running NT 4.x with rma.exe running) I get "error 301 - cannot retrieve information". This happen whenever I type in IP-adress (ie. 10.10.10.201). When I change to NETBIOS-name everything is fine. Is this a feature or a bug? ;-D
Should I allways use NETBIOS-name/s when working through RMAs, since local RPC calls (within a local LAN) is NETBIOS-trafic? If yes.. then You should consider to change this, since NETBIOS-names could get mixed up and make HM+RMA confused. It's more secure to specify an IP-address.
Cheers,
Hans Mosegaard |
|
Back to top |
|
|
KS-Soft
Joined: 03 Apr 2002 Posts: 12801 Location: USA
|
Posted: Tue Jul 22, 2003 2:50 pm Post subject: |
|
|
Its not RMA's feature, its feature of the Windows. Windows API function RegConnectRegistry fails when you provide IP address instead of netbios name.
Regards
Alex |
|
Back to top |
|
|
|
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum
|
Powered by phpBB © 2001, 2005 phpBB Group
|