problem with "tune up the reply value "

All questions related to installations, configurations and maintenance of Advanced Host Monitor (including additional tools such as RMA for Windows, RMA Manager, Web Servie, RCC).
Post Reply
menno
Posts: 158
Joined: Fri May 21, 2010 1:27 am

problem with "tune up the reply value "

Post by menno »

hi team
Just a small question
i can not find the good "string" for my "tune up the reply value " message...
i allready read this page :
https://www.ks-soft.net/hostmon.eng/tes ... uneupreply

but i cannot find the good string for it. :-?
I have a SNmP test thats reads the network ports of our switch
snmp oid : 1.3.6.1.2.1.2.2.1.8.1 gives 1 as UP en 2 as DOWN

i want to have the tune up the reply value in HM as UP and DOWN and NOT like 1 or 2
Can you please help me with this many thanks
menno
KS-Soft
Posts: 13012
Joined: Wed Apr 03, 2002 6:00 pm
Location: USA
Contact:

Post by KS-Soft »

if ('%SuggestedReply%'==1) UP; if ('%SuggestedReply%'==2) DOWN; else [%SuggestedReply%]

Regards
Alex
menno
Posts: 158
Joined: Fri May 21, 2010 1:27 am

Post by menno »

this worked great
thanks
m